68 C Linear Sensor Cable FT-68. Wire resistance: 0.10Ω/m. PVC - material. Approvals : FM, Ul, cUL, KFI, Price per linear mater, 100m coils.

Indicator light with buzzer. 24Vdc power supply required. High brightness LED lighting. Polycarbonate case with transparent front. White color. Included “EXTINGUISHING SYSTEM ACTIVATED” label. CPR certificate EN54-3.

Release manual call point. Yellow color. With test key, surface mount. Protective plastic cover included. Use for indoor applications. Includes resistance of 100 Ohm -2W. Dimensions: 98 x 98 x 48 mm.

Abort manual call point. Color blue. With test key, surface mount. Protective plastic cover included. Indoor use. Includes resistance of 100 Ohm -2W. Dimensions: 98 x 98 x 48 mm.

Extinguishing control panel for 1 risk (3 detection zones). 1 output for the activation of the bottle and 1 output for activating the sign, 2 inputs for monitoring the bottle, manual call point inputs: release, abort and pause, 2 sounder outputs for the two possible states extinguishing process, configurable extinction fire delay, 3 modes of operation of the extinguishing block: Manual, automatic and canceled, 2 inputs for monitoring the enclosure: door and ventilation. Historical event log. Possibility to connect to PC via USB for complex programming and event download. Integrable to addressable systems directly from the addressable loop. Certificate EN12094/1 and CPR EN54-2 and EN54-4. Dimensions: 443 x 268 x 109 mm. Requires 2 BTD-1207 batteries (not included).

Indoor alarm sounder with beacon. 32 selectable tones. Power at 24Vdc / 8mA at 36mA according to tone. IP21. Red color. Acoustic power 78 up to 116 dB according to tone. CPR certificate EN54-3. Dimensions: 85 x 75 mm.

Conventional manual call point, with test key, for surface installation. Suitable for indoor. Red color. Includes resistance of 100 Ohm.-2W. Dimensions: 98 x 98 x 48 mm. CPR certificate EN54-11.

Remote indicator for 200 and 200A detectors series 200A. Very low power consumption and high luminosity. Installed in closed or concealed enclosures. Dimensions: 69 x 26 mm

Conventional heat detector (fixed temperature 78ºC). Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.

Conventional heat detector (58°C fixed temperature and 8ºC/min thermal rate of rise). Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.

Conventional optical and heat detector. Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.

Conventional optical smoke detector. Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.

Addressable loop gateway card for conventional CCD-100 and CCD-103 panels range. Allows alarms and faults communication from the conventional control panel to the addressable loop to a CAD-150 control panel range.

Communication card for modular addressable control panels CAD-250. Includes Ethernet port, RS485 output for network connection of control panels (T-Network), 2 x RS485 for integrations, output for serial printer. Includes electric isolation circuit between nodes. 1.000 meters maximum distance between nodes.

Bidirectional repeater of the CAD-250 series addressable system, allows the control of 64 nodes on T-Network. Shows control panels events. Network installation on ring or bus. 10” graphic touch display with graphic management. Includes RS485 communication. Network drivers on board by default. ABS plastic cabinet with flush mounting capabilities. Power supply: 90 to 264 Vac and 2 external power supply inputs of 21 – 28 Vcc. Dimensions: 282 x 240 x 102mm.

The Modular addressable MCFA with 2 Loops (expandable to 32) features 10” touch screen with graphic management. 2048 programmable zones, 256 areas and 1024 groups. 100.000 event history logs, free configuration and maintenance software, USB and Ethernet configuration ports, 2 supervised sounder outputs and 2 free relay outputs. Auxiliary output of 24V 500 mA. Able to be networked up to 64 control panels (T-Network). Ethernet on board for programming and remote maintenance. Connectivity to Detnov Cloud. Metal box. Multilingual. CPR certificate EN 54-2 and EN 54-4. Requires 2 batteries BTD-1224 (not included). Dimensions: 533 x 453 x 212 mm.

The Modular addressable MCFA with 2 Loops (expandable to 32) features 10” touch screen with graphic management. 2048 programmable zones, 256 areas and 1024 groups. 100.000 event history logs, free configuration and maintenance software, USB and Ethernet configuration ports, 2 supervised sounder outputs and 2 free relay outputs. Auxiliary output of 24V 500 mA. Able to be networked up to 64 control panels (T-Network). Ethernet on board for programming and remote maintenance. Connectivity to Detnov Cloud. Metal box. Multilingual. CPR certificate EN 54-2 and EN 54-4. Requires 2 batteries BTD-1224 (not included). Dimensions: 533 x 453 x 212 mm.

The Modular addressable MCFA with 6 Loops (expandable to 32) features 10” touch screen with graphic management. 2048 programmable zones, 256 areas and 1024 groups. 100.000 event history logs, free configuration and maintenance software, USB and Ethernet configuration ports, 2 supervised sounder outputs and 2 free relay outputs. Auxiliary output of 24V 500 mA. Able to be networked up to 64 control panels (T-Network). Ethernet on board for programming and remote maintenance. Connectivity to Detnov Cloud. Metal box. Multilingual. CPR certificate EN 54-2 and EN 54-4. Requires 2 batteries BTD-1224 (not included). Dimensions: 533 x 453 x 212 mm.

The Modular addressable MCFA with 4 Loops (expandable to 32) features 10” touch screen with graphic management. 2048 programmable zones, 256 areas and 1024 groups. 100.000 event history logs, free configuration and maintenance software, USB and Ethernet configuration ports, 2 supervised sounder outputs and 2 free relay outputs. Auxiliary output of 24V 500 mA. Able to be networked up to 64 control panels (T-Network). Ethernet on board for programming and remote maintenance. Connectivity to Detnov Cloud. Metal box. Multilingual. CPR certificate EN 54-2 and EN 54-4. Requires 2 batteries BTD-1224 (not included). Dimensions: 533 x 453 x 212 mm.

 The Modular addressable MCFA with 2 Loops (expandable to 32) features 10” touch screen with graphic management. 2048 programmable zones, 256 areas and 1024 groups. 100.000 event history logs, free configuration and maintenance software, USB and Ethernet configuration ports, 2 supervised sounder outputs and 2 free relay outputs. Auxiliary output of 24V 500 mA. Able to be networked up to 64 control panels (T-Network). Ethernet on board for programming and remote maintenance. Connectivity to Detnov Cloud. Metal box. Multilingual. CPR certificate EN 54-2 and EN 54-4. Requires 2 batteries BTD-1224 (not included). Dimensions: 533 x 453 x 212 mm.

LONG RANGE DISTANCE KIT FOR BEAM DETECTOR FIREBEAM XTRA. USE THIS FOR DISTANCES OVER 140 METERS AND UP TO A MAXIMUM OF 160 METERS.

MID RANGE DISTANCE KIT FOR BEAM DETECTOR FIREBEAM XTRA. USE THIS FOR DISTANCES OVER 70 METERS AND UP TO 140 METERS.

BEAM DETECTOR FOR DISTANCES OVER 7 METERS AND UP TO 70 METERS, EXPANDABLE UP TO 140 OR 160 METERS WITH EXTENSION KITS. CONFIGURATION AND MAINTENANCE VIA APP. IP65 FOR USE OUTDOORS OR INDOOR WITH EXTREME ENVIRONMENTAL CONDITIONS. 24VDC POWER SUPPLY. CPR CERTIFICATE EN 54-12. DIMENSIONS: DETECTOR 180X155X137MM, CONTROLLER 185X120X62MM.

BEAM DETECTOR FOR DISTANCES OVER 7 METERS AND UP TO 70 METERS, EXPANDABLE UP TO 140 OR 160 METERS WITH EXTENSION KITS. SEPARATED HEAD DETECTOR AND CONTROLLER FOR EASY ACCESS TO PROGRAMMING. IP65 FOR USE OUTDOORS OR INDOOR WITH EXTREME ENVIRONMENTAL CONDITIONS. 24VDC POWER SUPPLY. CPR CERTIFICATE EN 54-12. DIMENSIONS: DETECTOR 180X155X137MM, CONTROLLER 185X120X62MM.

CONVENTIONAL FIRE ALARM CONTROL PANEL FOR 12 ZONES MOUNTED ON ABS PLASTIC HOUSING. FLUSH MOUNT OPTION. DISCRIMINATES BETWEEN DETECTOR ALARM AND MANUAL CALL POINTS ALARM. UP TO 32 DETECTORS PER ZONE. POSSIBILITY TO CONNECT TO PC VIA USB FOR COMPLEX PROGRAMMING. INTEGRABLE TO ADDRESSABLE SYSTEMS DIRECTLY TO THE LOOP. IT HAS TWO CONFIGURABLE SUPERVISED SIREN OUTPUTS (500 MA EACH OUTPUT), ALARM AND FAULT RELAY OUTPUTS FREE OF VOLTAGE, AUXILIARY 24V OUTPUT (500 MA MAXIMUM CONSUMPTION), 24V RESETTABLE OUTPUT (500 MA MAXIMUM CONSUMPTION) AND 1 EXTERNAL INPUT PROGRAMMABLE. TSD100: 4 SUPERVISED SIREN OUTPUTS, TMD-100: MODBUS OUTPUT FOR INTEGRATIONS, TCD: CONTACT ID PROTOCOL FOR CONNECTION TO CRA, TPLD-100: INTEGRATION TO ADDRESSABLE LOOP). TELE MAINTENANCE AND REMOTE CONTROL THROUGH TED-151-CL CARD (DETNOV CLOUD). MULTILINGUAL KEYBOARD. CPR CERTIFICATE EN54-2 , EN54-4 AND EN54-13. DIMENSIONS: 443 X 268 X 109 MM. REQUIRES 2 BTD-1207 BATTERIES (NOT INCLUDED).

CONVENTIONAL FIRE ALARM CONTROL PANEL FOR 8 ZONES MOUNTED ON ABS PLASTIC HOUSING. FLUSH MOUNT OPTION. DISCRIMINATES BETWEEN DETECTOR ALARM AND MANUAL CALL POINTS ALARM. UP TO 32 DETECTORS PER ZONE. POSSIBILITY TO CONNECT TO PC VIA USB FOR COMPLEX PROGRAMMING. INTEGRABLE TO ADDRESSABLE SYSTEMS DIRECTLY TO THE LOOP. IT HAS TWO CONFIGURABLE SUPERVISED SIREN OUTPUTS (500 MA EACH OUTPUT), ALARM AND FAULT RELAY OUTPUTS FREE OF VOLTAGE, AUXILIARY 24V OUTPUT (500 MA MAXIMUM CONSUMPTION), 24V RESETTABLE OUTPUT (500 MA MAXIMUM CONSUMPTION) AND 1 EXTERNAL INPUT PROGRAMMABLE. TSD100: 4 SUPERVISED SIREN OUTPUTS, TMD-100: MODBUS OUTPUT FOR INTEGRATIONS, TPLD-100: INTEGRATION TO ADDRESSABLE LOOP). TELE MAINTENANCE AND REMOTE CONTROL THROUGH TED-151-CL CARD (DETNOV CLOUD). MULTILINGUAL KEYBOARD. CPR CERTIFICATE EN54-2 ,EN54-4 AND EN54-13. DIMENSIONS: 443 X 268 X 109 MM. REQUIRES 2 BTD-1207 BATTERIES (NOT INCLUDED).

ADDRESSABLE LOOP SOUNDER WITH BEACON AND BUILT-IN ISOLATOR. LOW POWER CONSUMPTION. 32 TONES AND 3 CONFIGURABLE VOLUMES (LOW, MEDIUM, HIGH). ACOUSTIC POWER 76 DBA TO 117 DBA DEPENDING ON THE SELECTED TONE. IT TAKES JUST ONE ADDRESS IN THE LOOP. RED COLOR. IP33C. DEEP BASE. CPR CERTIFICATE EN 54-3 AND EN 54-17. DIMENSIONS: 100 X 75 MM

ADDRESSABLE LOOP SOUNDER WITH ISOLATOR. LOW POWER CONSUMPTION, ACOUSTIC POWER 82.5 DB. IT TAKES JUST ONE ADDRESS IN THE LOOP. COLOR RED. FOR INDOOR USE. IP21. CPR CERTIFICATE EN54-3 AND EN54-17. DIMENSIONS: 65 X 90 MM.

ADDRESSABLE MANUAL CALL POINT. LED STATUS INDICATOR AND TEST KEY. ALLOWS INSTALLATION WITHOUT POLARITY. RED COLOR. CPR CERTIFICATE EN54-11. DIMENSIONS: 98 X 98 X 48 MM.

ADDRESSABLE HIGH TEMPERATURE DETECTOR (FIXED AT 78ºC), WITH ALGORITHM VERIFICATION. LED STATUS INDICATOR AND OUTPUT FOR REMOTE PILOT INDICATOR PAD-10 OR BUZZER BUD-200.. BLACK COLOR. ALLOWS INSTALLATION WITHOUT POLARITY. REQUIRES CONNECTION BASE Z-200-B OR Z-200-B-H. ANTI-THEFT SYSTEM (ONLY WITH Z-200). CPR CERTIFICATE EN 54-5. DIMENSIONS: 100 X 40 MM.

ADDRESSABLE HEAT (58°C FIXED TEMPERATURE AND THERMAL RATE OF RISE) DETECTOR, WITH ALGORITHM VERIFICATION. LED STATUS INDICATOR AND OUTPUT FOR REMOTE PILOT INDICATOR PAD-10 OR BUZZER BUD-200. BLACK COLOR. ALLOWS INSTALLATION WITHOUT POLARITY. REQUIRES BASE Z-200-B OR Z-200-B-H. ANTI-THEFT SYSTEM (ONLY WITH Z-200). CPR CERTIFICATE EN 54-5. DIMENSIONS: 100 X 40 MM.

ADDRESSABLE OPTICAL & HEAT DETECTOR, WITH DIRT COMPENSATION AND ALGORITHM VERIFICATION. LED STATUS INDICATOR AND OUTPUT FOR REMOTE PILOT INDICATOR PAD-10 OR BUZZER BUD-200. BLACK COLOR. ALLOWS INSTALLATION WITHOUT POLARITY. REQUIRES CONNECTION BASE Z-200-B OR Z-200-B-H. ANTI-THEFT SYSTEM (ONLY WITH Z-200). CPR CERTIFICATES EN 54-5 AND EN 54-7. DIMENSIONS: 100 X 40 MM.